The OMD-32 Oil-in-Water Monitor has been designed specifically for use in conjunction with oil-water separator units. The OMD-32 has been constructed using technology of the DECKMA HAMBURG OMD series industrial instruments and 15ppm Bilge Alarm Monitors, that have a specification and performance which exceeds the requirements of the International Maritime Organization specifications for 15ppm Oil-in-Water Monitors contained in Resolution MEPC. 107 (49).The OMD-32 unit is supplied with 2 works-adjusted alarms at 10 ppm. Other set points are possible (e.g. 100ppm) and can be adjusted on site at any time by using the buttons at the front panel.If an alarm set point is exceeded, the alarms are visible at the front panel and the appropriate relays are switched. In case of malfunction the System LED at the front panel will change from blinking green to permanent red, and a system fault relay contact is switched.
A 0(4) - 20 mA signal output is available for driving a recorder or external meter.
Property | Value |
---|---|
Range* | 0 – 200 ppm |
Resolution* | 1ppm (0.1 ppm below 10ppm) |
Accuracy | up to +/- 1ppm below 10ppm |
Response time | < 5s |
Sample Water Pressure | max. 10 bar |
Sample Flow | typ. 2 Liter / min |
Sample Water Temperature | up to 90° C |
Power Supply | 24 V – 240V AC or DC |
Power Consumption | < 10 VA |
ppm Alarm | 2 adjustable ( independent, entire range ) |
ppm Alarms delay | 2 adjustable ( independent, from 1 sec. up to 540 sec.) |
ppm Alarm visual indication | 2 Red LEDs |
ppm Alarms Contact Rating | 2 Potential free 1 pole change over contacts, 3 A / 240 VAC |
System Fault Alarm visual indication: | Red LED |
System Fault Alarm Contact Rating | Potential free 1 pole change over contact, 3 A / 240 VAC |
Output Signal | 0(4) – 20 mA, ext. Load < 150 W, Output range adjustable |
Cleaning System* | Automatic, pneumatically operated |
Cleaning system air pressure* | 2.5 - 6 bar, typ. <0.1 Liter / hour |
Ambient Temperature | + 1 to + 55° C |
Size* | 360 mm W x 240 mm H x 120 mm D |
Distance(Computer Unit to Measuring Cell) | Option: up to 5m upon request |
Degree of Protection | IP 65 |
Weight* | 4 kg |
Pipe Connections* | R ¼" Female |
* Different versions and configurations available. |